Getting Started with Kubernetes

Network Operator Deployment Guide

Warning

The Network Operator Release Notes chapter is available here.

NVIDIA Network Operator leverages Kubernetes CRDs and Operator SDK to manage networking related components in order to enable fast networking, RDMA and GPUDirect for workloads in a Kubernetes cluster. The Network Operator works in conjunction with the GPU-Operator to enable GPU-Direct RDMA on compatible systems.

The goal of the Network Operator is to manage the networking related components, while enabling execution of RDMA and GPUDirect RDMA workloads in a Kubernetes cluster. This includes:

  • NVIDIA Networking drivers to enable advanced features - enp1 netdcreate, an NV-IPAM IPPool

  • Kubernetes device plugins to provide hardware resources required for an accelerated network

  • Kubernetes secondary network components for network intensive workloads

Prerequisites

  1. You have the kubectl and helm CLIs available on a client machine.

    You can run the following commands to install the Helm CLI:

    $ curl -fsSL -o get_helm.sh https://raw.githubusercontent.com/helm/helm/master/scripts/get-helm-3 \
        && chmod 700 get_helm.sh \
        && ./get_helm.sh
    
  2. Nodes must be configured with a container engine such CRI-O or containerd.

  3. If your cluster uses Pod Security Admission (PSA) to restrict the behavior of pods, label the namespace for the Operator to set the enforcement policy to privileged:

    $ kubectl create ns nvidia-network-operator
    $ kubectl label --overwrite ns nvidia-network-operator pod-security.kubernetes.io/enforce=privileged
    
  4. Node Feature Discovery (NFD) is a dependency for the Operator on each node. By default, NFD master and worker are automatically deployed by the Operator. If NFD is already running in the cluster, then you must disable deploying NFD when you install the Operator. by setting nfd.enabled=false Helm value

    One way to determine if NFD is already running in the cluster is to check for a NFD label on your nodes:

    $ kubectl get nodes -o json | jq '.items[].metadata.labels | keys | any(startswith("feature.node.kubernetes.io"))'
    

    If the command output is true, then NFD is already running in the cluster.

    Note

    NFD needs to support NodeFeatureRules API or it should be configured to expose the needed NIC labels. Deploying NFD from either NVIDIA Network Operator or NVIDIA GPU Operator will have the correct configurations for both Operators.

Network Operator Deployment on Vanilla Kubernetes Cluster

Warning

It is recommended to have dedicated control plane nodes for Vanilla Kubernetes deployments with NVIDIA Network Operator.

The default installation via Helm as described below will deploy the Network Operator and related CRDs, after which an additional step is required to create a NicClusterPolicy custom resource with the configuration that is desired for the cluster.

For more information on NicClusterPolicy custom resource, please refer to the Network-Operator Project Sources.

The provided Helm chart contains various parameters to facilitate the creation of a NicClusterPolicy custom resource upon deployment.

Warning

Each Network Operator Release has a set of default version values for the various components it deploys. It is recommended that these values will not be changed. Testing and validation were performed with these values, and there is no guarantee of interoperability nor correctness when different versions are used.

Add NVIDIA NGC Helm repository
helm repo add nvidia https://helm.ngc.nvidia.com/nvidia
Update helm repositories
helm repo update

Install Network Operator from the NVIDIA NGC chart using the default values:

 helm install network-operator nvidia/network-operator \
   -n nvidia-network-operator \
   --create-namespace \
   --version v24.10.0-beta.1 \
   --wait
View deployed resources
kubectl -n nvidia-network-operator get pods

Install the Network Operator from the NVIDIA NGC chart using custom values:

Warning

Since several parameters should be provided when creating custom resources during operator deployment, it is recommended to use a configuration file. While it is possible to override the parameters via CLI, we recommend to avoid the use of CLI arguments in favor of a configuration file.

helm show values nvidia/network-operator --version v24.10.0-beta.1 > values.yaml
 helm install network-operator nvidia/network-operator \
   -n nvidia-network-operator \
   --create-namespace \
   --version v24.10.0-beta.1 \
   -f ./values.yaml \
   --wait

Deployment Examples

Warning

Since several parameters should be provided when creating custom resources during operator deployment, it is recommended to use a configuration file. While it is possible to override the parameters via CLI, we recommend to avoid the use of CLI arguments in favor of a configuration file.

Below are deployment examples, which the values.yaml file provided to the Helm during the installation of the network operator. This was achieved by running:

helm install -f ./values.yaml -n nvidia-network-operator --create-namespace --wait nvidia/network-operator network-operator

Network Operator Deployment with RDMA Shared Device Plugin

First install the Network Operator with NFD enabled:

values.yaml:

nfd:
  enabled: true

Once the Network Operator is installed create a NicClusterPolicy with * DOCA driver * RDMA Shared device plugin configured to a netdev with name ens1f0.

Note: You may need to change the interface names in the NicClusterPolicy to those used by your target nodes.

 apiVersion: mellanox.com/v1alpha1
 kind: NicClusterPolicy
 metadata:
   name: nic-cluster-policy
 spec:
   ofedDriver:
     image: doca-driver
     repository: nvcr.io/nvidia/mellanox
     version: 24.10-0.3.2.0-0
     forcePrecompiled: false
     imagePullSecrets: []
     terminationGracePeriodSeconds: 300
     startupProbe:
       initialDelaySeconds: 10
       periodSeconds: 20
     livenessProbe:
       initialDelaySeconds: 30
       periodSeconds: 30
     readinessProbe:
       initialDelaySeconds: 10
       periodSeconds: 30
     upgradePolicy:
       autoUpgrade: true
       maxParallelUpgrades: 1
       safeLoad: false
       drain:
         enable: true
         force: true
         podSelector: ""
         timeoutSeconds: 300
         deleteEmptyDir: true
   rdmaSharedDevicePlugin:
     # [map[ifNames:[ens1f0] name:rdma_shared_device_a]]
     image: k8s-rdma-shared-dev-plugin
     repository: ghcr.io/mellanox
     version: sha-4f3eb2224b8b5f97be3f17441ddee8d41753b7d5
     imagePullSecrets: []
     # The config below directly propagates to k8s-rdma-shared-device-plugin configuration.
     # Replace 'devices' with your (RDMA capable) netdevice name.
     config: |
       {
         "configList": [
           {
             "resourceName": "rdma_shared_device_a",
             "rdmaHcaMax": 63,
             "selectors": {
               "vendors": [],
               "deviceIDs": [],
               "drivers": [],
               "ifNames": ["ens1f0"],
               "linkTypes": []
             }
           }
         ]
       }

Network Operator Deployment with Multiple Resources in RDMA Shared Device Plugin

First install the Network Operator with NFD enabled:

values.yaml:

nfd:
  enabled: true

Once the Network Operator is installed create a NicClusterPolicy with: * DOCA driver * RDMA Shared Device pluging with two RDMA resources - the first mapped to ens1f0 and ens1f1 and the second mapped to ens2f0 and ens2f1.

Note: You may need to change the interface names in the NicClusterPolicy to those used by your target nodes.

 apiVersion: mellanox.com/v1alpha1
 kind: NicClusterPolicy
 metadata:
   name: nic-cluster-policy
 spec:
   ofedDriver:
     image: doca-driver
     repository: nvcr.io/nvidia/mellanox
     version: 24.10-0.3.2.0-0
     forcePrecompiled: false
     imagePullSecrets: []
     terminationGracePeriodSeconds: 300
     startupProbe:
       initialDelaySeconds: 10
       periodSeconds: 20
     livenessProbe:
       initialDelaySeconds: 30
       periodSeconds: 30
     readinessProbe:
       initialDelaySeconds: 10
       periodSeconds: 30
     upgradePolicy:
       autoUpgrade: true
       maxParallelUpgrades: 1
       safeLoad: false
       drain:
         enable: true
         force: true
         podSelector: ""
         timeoutSeconds: 300
         deleteEmptyDir: true
   rdmaSharedDevicePlugin:
     # [map[ifNames:[ens1f0 ens1f1] name:rdma_shared_device_a] map[ifNames:[ens2f0 ens2f1] name:rdma_shared_device_b]]
     image: k8s-rdma-shared-dev-plugin
     repository: ghcr.io/mellanox
     version: sha-4f3eb2224b8b5f97be3f17441ddee8d41753b7d5
     imagePullSecrets: []
     # The config below directly propagates to k8s-rdma-shared-device-plugin configuration.
     # Replace 'devices' with your (RDMA capable) netdevice name.
     config: |
       {
         "configList": [
           {
             "resourceName": "rdma_shared_device_a",
             "rdmaHcaMax": 63,
             "selectors": {
               "vendors": [],
               "deviceIDs": [],
               "drivers": [],
               "ifNames": ["ens1f0","ens1f1"],
               "linkTypes": []
             }
           },
           {
             "resourceName": "rdma_shared_device_b",
             "rdmaHcaMax": 63,
             "selectors": {
               "vendors": [],
               "deviceIDs": [],
               "drivers": [],
               "ifNames": ["ens2f0","ens2f1"],
               "linkTypes": []
             }
           }
         ]
       }

Network Operator Deployment with a Secondary Network

First install the Network Operator with NFD enabled:

values.yaml:

nfd:
  enabled: true

Once the Network Operator is installed create a NicClusterPolicy with the following enabled: * Secondary network * Multus CNI * Container-networking-plugins CNI plugins * IPAM Plugin

 apiVersion: mellanox.com/v1alpha1
 kind: NicClusterPolicy
 metadata:
   name: nic-cluster-policy
 spec:
   secondaryNetwork:
     cniPlugins:
       image: plugins
       repository: ghcr.io/k8snetworkplumbingwg
       version: v1.5.0
       imagePullSecrets: []
     multus:
       image: multus-cni
       repository: ghcr.io/k8snetworkplumbingwg
       version: v4.1.0
       imagePullSecrets: []
     ipamPlugin:
       image: whereabouts
       repository: ghcr.io/k8snetworkplumbingwg
       version: v0.7.0
       imagePullSecrets: []

Network Operator Deployment with NVIDIA-IPAM

First install the Network Operator with NFD enabled: values.yaml:

nfd:
  enabled: true
Once the Network Operator is installed deploy a NicClusterPolicy with the following enabled:
  • Secondary network

  • Multus CNI

  • Container Networking plugins

  • NVIDIA-IPAM plugin

 apiVersion: mellanox.com/v1alpha1
 kind: NicClusterPolicy
 metadata:
   name: nic-cluster-policy
 spec:
   secondaryNetwork:
     cniPlugins:
       image: plugins
       repository: ghcr.io/k8snetworkplumbingwg
       version: v1.5.0
       imagePullSecrets: []
     multus:
       image: multus-cni
       repository: ghcr.io/k8snetworkplumbingwg
       version: v4.1.0
       imagePullSecrets: []
   nvIpam:
     image: nvidia-k8s-ipam
     repository: ghcr.io/mellanox
     version: v0.2.0
     imagePullSecrets: []
     enableWebhook: false

To create an NV-IPAM IPPool, apply:

apiVersion: nv-ipam.nvidia.com/v1alpha1
kind: IPPool
metadata:
  name: my-pool
  namespace: nvidia-network-operator
spec:
  subnet: 192.168.0.0/24
  perNodeBlockSize: 100
  gateway: 192.168.0.1

Example of a MacvlanNetwork that uses NVIDIA-IPAM:

apiVersion: mellanox.com/v1alpha1
kind: MacvlanNetwork
metadata:
  name: example-macvlannetwork
spec:
  networkNamespace: "default"
  master: "ens2f0"
  mode: "bridge"
  mtu: 1500
  ipam: |
    {
      "type": "nv-ipam",
      "poolName": "my-pool"
    }

Network Operator Deployment with a Host Device Network

In this mode, the Network Operator could be deployed on virtualized deployments as well. It supports both Ethernet and InfiniBand modes. From the Network Operator perspective, there is no difference between the deployment procedures. To work on a VM (virtual machine), the PCI passthrough must be configured for SR-IOV devices. The Network Operator works both with VF (Virtual Function) and PF (Physical Function) inside the VMs.

Warning

If the Host Device Network is used without the MLNX_OFED driver, the following packages should be installed:

  • the linux-generic package on Ubuntu hosts

  • the kernel-modules-extra package on the RedHat-based hosts

First install the Network Operator with NFD enabled: values.yaml:

nfd:
  enabled: true
Once the Network Operator is installed deploy a NicClusterPolicy with:
  • SR-IOV device plugin configured with a single SR-IOV resource pool

  • Secondary network

  • Multus CNI

  • Container Networking plugins

  • IPAM plugin

 apiVersion: mellanox.com/v1alpha1
 kind: NicClusterPolicy
 metadata:
   name: nic-cluster-policy
 spec:
   sriovDevicePlugin:
     image: sriov-network-device-plugin
     repository: ghcr.io/k8snetworkplumbingwg
     version: v3.7.0
     imagePullSecrets: []
     config: |
       {
         "resourceList": [
           {
             "resourcePrefix": "nvidia.com",
             "resourceName": "hostdev",
             "selectors": {
               "vendors": ["15b3"],
               "devices": [],
               "drivers": [],
               "pfNames": [],
               "pciAddresses": [],
               "rootDevices": [],
               "linkTypes": [],
               "isRdma": true
             }
           }
         ]
       }
   secondaryNetwork:
     cniPlugins:
       image: plugins
       repository: ghcr.io/k8snetworkplumbingwg
       version: v1.5.0
       imagePullSecrets: []
     multus:
       image: multus-cni
       repository: ghcr.io/k8snetworkplumbingwg
       version: v4.1.0
       imagePullSecrets: []
     ipamPlugin:
       image: whereabouts
       repository: ghcr.io/k8snetworkplumbingwg
       version: v0.7.0
       imagePullSecrets: []

Following the deployment, the network operator should be configured, and K8s networking should be deployed to use it in pod configuration.

The host-device-net.yaml configuration file for such a deployment:

apiVersion: mellanox.com/v1alpha1
kind: HostDeviceNetwork
metadata:
  name: hostdev-net
spec:
  networkNamespace: "default"
  resourceName: "nvidia.com/hostdev"
  ipam: |
    {
      "type": "whereabouts",
      "datastore": "kubernetes",
      "kubernetes": {
        "kubeconfig": "/etc/cni/net.d/whereabouts.d/whereabouts.kubeconfig"
      },
      "range": "192.168.3.225/28",
      "exclude": [
       "192.168.3.229/30",
       "192.168.3.236/32"
      ],
      "log_file": "/var/log/whereabouts.log",
      "log_level": "info"
    }

The host-device-net-ocp.yaml configuration file for such a deployment in the OpenShift Platform:

apiVersion: mellanox.com/v1alpha1
kind: HostDeviceNetwork
metadata:
  name: hostdev-net
spec:
  networkNamespace: "default"
  resourceName: "nvidia.com/hostdev"
  ipam: |
    {
      "type": "whereabouts",
      "range": "192.168.3.225/28",
      "exclude": [
       "192.168.3.229/30",
       "192.168.3.236/32"
      ]
    }

The pod.yaml configuration file for such a deployment:

apiVersion: v1
kind: Pod
metadata:
  name: hostdev-test-pod
  annotations:
    k8s.v1.cni.cncf.io/networks: hostdev-net
spec:
  restartPolicy: OnFailure
  containers:
  - image:
    name: mofed-test-ctr
    securityContext:
      capabilities:
        add: [ "IPC_LOCK" ]
    resources:
      requests:
        nvidia.com/hostdev: 1
      limits:
        nvidia.com/hostdev: 1
    command:
    - sh
    - -c
    - sleep inf

Network Operator Deployment with a Host Device Network and Macvlan Network

In this combined deployment, different NVIDIA NICs are used for RDMA Shared Device Plugin and SR-IOV Network Device Plugin in order to work with a Host Device Network or a Macvlan Network on different NICs. It is impossible to combine different networking types on the same NICs. The same principle should be applied for other networking combinations.

First install the Network Operator with NFD enabled: values.yaml:

nfd:
  enabled: true
Once the Network Operator is installed deploy a NicClusterPolicy with:
  • RDMA shared device plugin with

  • SR-IOV device plugin, single SR-IOV resource pool

  • Secondary network

  • Multus CNI

  • Container-networking-plugins CNI plugins

  • RDMA Shared device plugin

  • Whereabouts IPAM CNI plugin

 apiVersion: mellanox.com/v1alpha1
 kind: NicClusterPolicy
 metadata:
   name: nic-cluster-policy
 spec:
   rdmaSharedDevicePlugin:
     # [map[linkTypes:[ether] name:rdma_shared_device_a]]
     image: k8s-rdma-shared-dev-plugin
     repository: ghcr.io/mellanox
     version: sha-4f3eb2224b8b5f97be3f17441ddee8d41753b7d5
     imagePullSecrets: []
     # The config below directly propagates to k8s-rdma-shared-device-plugin configuration.
     # Replace 'devices' with your (RDMA capable) netdevice name.
     config: |
       {
         "configList": [
           {
             "resourceName": "rdma_shared_device_a",
             "rdmaHcaMax": 63,
             "selectors": {
               "vendors": [],
               "deviceIDs": [],
               "drivers": [],
               "ifNames": [],
               "linkTypes": ["ether"]
             }
           }
         ]
       }
   sriovDevicePlugin:
     image: sriov-network-device-plugin
     repository: ghcr.io/k8snetworkplumbingwg
     version: v3.7.0
     imagePullSecrets: []
     config: |
       {
         "resourceList": [
           {
             "resourcePrefix": "nvidia.com",
             "resourceName": "hostdev",
             "selectors": {
               "vendors": [],
               "devices": [],
               "drivers": [],
               "pfNames": [],
               "pciAddresses": [],
               "rootDevices": [],
               "linkTypes": ["IB"],
               "isRdma": true
             }
           }
         ]
       }
   secondaryNetwork:
     cniPlugins:
       image: plugins
       repository: ghcr.io/k8snetworkplumbingwg
       version: v1.5.0
       imagePullSecrets: []
     multus:
       image: multus-cni
       repository: ghcr.io/k8snetworkplumbingwg
       version: v4.1.0
       imagePullSecrets: []
     ipamPlugin:
       image: whereabouts
       repository: ghcr.io/k8snetworkplumbingwg
       version: v0.7.0
       imagePullSecrets: []

For pods and network configuration examples please refer to the corresponding sections: Network Operator Deployment with the RDMA Shared Device Plugin and Network Operator Deployment with a Host Device Network.

Network Operator Deployment with an IP over InfiniBand (IPoIB) Network

In this mode, the Network Operator could be deployed on virtualized deployments as well. It supports both Ethernet and InfiniBand modes. From the Network Operator perspective, there is no difference between the deployment procedures. To work on a VM (virtual machine), the PCI passthrough must be configured for SR-IOV devices. The Network Operator works both with VF (Virtual Function) and PF (Physical Function) inside the VMs.

First install the Network Operator with NFD enabled: values.yaml:

nfd:
  enabled: true

Once the Network Operator is installed create a NicClusterPolicy with: * DOCA driver * RDMA shared device plugin * Secondary network * Multus CNI * IPoIB CNI * Whereabouts IPAM CNI plugin

 apiVersion: mellanox.com/v1alpha1
 kind: NicClusterPolicy
 metadata:
   name: nic-cluster-policy
 spec:
   ofedDriver:
     image: doca-driver
     repository: nvcr.io/nvidia/mellanox
     version: 24.10-0.3.2.0-0
     forcePrecompiled: false
     imagePullSecrets: []
     terminationGracePeriodSeconds: 300
     startupProbe:
       initialDelaySeconds: 10
       periodSeconds: 20
     livenessProbe:
       initialDelaySeconds: 30
       periodSeconds: 30
     readinessProbe:
       initialDelaySeconds: 10
       periodSeconds: 30
     upgradePolicy:
       autoUpgrade: true
       maxParallelUpgrades: 1
       safeLoad: false
       drain:
         enable: true
         force: true
         podSelector: ""
         timeoutSeconds: 300
         deleteEmptyDir: true
   rdmaSharedDevicePlugin:
     # [map[ifNames:[ibs1f0] name:rdma_shared_device_a]]
     image: k8s-rdma-shared-dev-plugin
     repository: ghcr.io/mellanox
     version: sha-4f3eb2224b8b5f97be3f17441ddee8d41753b7d5
     imagePullSecrets: []
     # The config below directly propagates to k8s-rdma-shared-device-plugin configuration.
     # Replace 'devices' with your (RDMA capable) netdevice name.
     config: |
       {
         "configList": [
           {
             "resourceName": "rdma_shared_device_a",
             "rdmaHcaMax": 63,
             "selectors": {
               "vendors": [],
               "deviceIDs": [],
               "drivers": [],
               "ifNames": ["ibs1f0"],
               "linkTypes": []
             }
           }
         ]
       }
   secondaryNetwork:
     cniPlugins:
       image: plugins
       repository: ghcr.io/k8snetworkplumbingwg
       version: v1.5.0
       imagePullSecrets: []
     multus:
       image: multus-cni
       repository: ghcr.io/k8snetworkplumbingwg
       version: v4.1.0
       imagePullSecrets: []
     ipoib:
       image: ipoib-cni
       repository: ghcr.io/mellanox
       version: 428715a57c0b633e48ec7620f6e3af6863149ccf
     ipamPlugin:
       image: whereabouts
       repository: ghcr.io/k8snetworkplumbingwg
       version: v0.7.0
       imagePullSecrets: []

Following the deployment, the network operator should be configured, and K8s networking deployed to use it in the pod configuration.

The ipoib-net.yaml configuration file for such a deployment:

apiVersion: mellanox.com/v1alpha1
kind: IPoIBNetwork
metadata:
  name: example-ipoibnetwork
spec:
  networkNamespace: "default"
  master: "ibs1f0"
  ipam: |
    {
      "type": "whereabouts",
      "datastore": "kubernetes",
      "kubernetes": {
        "kubeconfig": "/etc/cni/net.d/whereabouts.d/whereabouts.kubeconfig"
      },
      "range": "192.168.5.225/28",
      "exclude": [
       "192.168.6.229/30",
       "192.168.6.236/32"
      ],
      "log_file" : "/var/log/whereabouts.log",
      "log_level" : "info",
      "gateway": "192.168.6.1"
    }

The ipoib-net-ocp.yaml configuration file for such a deployment in the OpenShift Platform:

apiVersion: mellanox.com/v1alpha1
kind: IPoIBNetwork
metadata:
  name: example-ipoibnetwork
spec:
  networkNamespace: "default"
  master: "ibs1f0"
  ipam: |
    {
      "type": "whereabouts",
      "range": "192.168.5.225/28",
      "exclude": [
       "192.168.6.229/30",
       "192.168.6.236/32"
      ]
    }

The pod.yaml configuration file for such a deployment:

apiVersion: v1
kind: Pod
metadata:
  name: iboip-test-pod
  annotations:
    k8s.v1.cni.cncf.io/networks: example-ipoibnetwork
spec:
  restartPolicy: OnFailure
  containers:
  - image:
    name: mofed-test-ctr
    securityContext:
      capabilities:
        add: [ "IPC_LOCK" ]
    resources:
      requests:
        rdma/rdma_shared_device_a: 1
      limits:
        edma/rdma_shared_device_a: 1
    command:
    - sh
    - -c
    - sleep inf

Network Operator Deployment for GPUDirect Workloads

GPUDirect requires the following:

  • NVIDIA DOCA Driver v5.5-1.0.3.2 or newer

  • GPU Operator v1.9.0 or newer

  • NVIDIA GPU and driver supporting GPUDirect e.g Quadro RTX 6000/8000 or NVIDIA T4/NVIDIA V100/NVIDIA A100

First install the Network Operator with NFD enabled: values.yaml:

nfd:
  enabled: true

Once the Network Operator is installed create a NicClusterPolicy with: * DOCA driver * SR-IOV Device Plugin * Secondary network * Multus CNI * Container Networking plugins * IPAM plugin

 apiVersion: mellanox.com/v1alpha1
 kind: NicClusterPolicy
 metadata:
   name: nic-cluster-policy
 spec:
   ofedDriver:
     image: doca-driver
     repository: nvcr.io/nvidia/mellanox
     version: 24.10-0.3.2.0-0
     forcePrecompiled: false
     imagePullSecrets: []
     terminationGracePeriodSeconds: 300
     startupProbe:
       initialDelaySeconds: 10
       periodSeconds: 20
     livenessProbe:
       initialDelaySeconds: 30
       periodSeconds: 30
     readinessProbe:
       initialDelaySeconds: 10
       periodSeconds: 30
     upgradePolicy:
       autoUpgrade: true
       maxParallelUpgrades: 1
       safeLoad: false
       drain:
         enable: true
         force: true
         podSelector: ""
         timeoutSeconds: 300
         deleteEmptyDir: true
   sriovDevicePlugin:
     image: sriov-network-device-plugin
     repository: ghcr.io/k8snetworkplumbingwg
     version: v3.7.0
     imagePullSecrets: []
     config: |
       {
         "resourceList": [
           {
             "resourcePrefix": "nvidia.com",
             "resourceName": "hostdev",
             "selectors": {
               "vendors": ["15b3"],
               "devices": [],
               "drivers": [],
               "pfNames": [],
               "pciAddresses": [],
               "rootDevices": [],
               "linkTypes": [],
               "isRdma": true
             }
           }
         ]
       }
   secondaryNetwork:
     cniPlugins:
       image: plugins
       repository: ghcr.io/k8snetworkplumbingwg
       version: v1.5.0
       imagePullSecrets: []
     multus:
       image: multus-cni
       repository: ghcr.io/k8snetworkplumbingwg
       version: v4.1.0
       imagePullSecrets: []
     ipamPlugin:
       image: whereabouts
       repository: ghcr.io/k8snetworkplumbingwg
       version: v0.7.0
       imagePullSecrets: []

host-device-net.yaml:

apiVersion: mellanox.com/v1alpha1
kind: HostDeviceNetwork
metadata:
   name: hostdevice-net
spec:
  networkNamespace: "default"
  resourceName: "hostdev"
  ipam: |
    {
      "type": "whereabouts",
      "datastore": "kubernetes",
      "kubernetes": {
        "kubeconfig": "/etc/cni/net.d/whereabouts.d/whereabouts.kubeconfig"
      },
      "range": "192.168.3.225/28",
      "exclude": [
       "192.168.3.229/30",
       "192.168.3.236/32"
      ],
      "log_file" : "/var/log/whereabouts.log",
      "log_level" : "info"
    }

The host-device-net-ocp.yaml configuration file for such a deployment in the OpenShift Platform:

apiVersion: mellanox.com/v1alpha1
kind: HostDeviceNetwork
metadata:
   name: hostdevice-net
spec:
  networkNamespace: "default"
  resourceName: "hostdev"
  ipam: |
    {
      "type": "whereabouts",
      "range": "192.168.3.225/28",
      "exclude": [
       "192.168.3.229/30",
       "192.168.3.236/32"
      ]
    }

host-net-gpudirect-pod.yaml

apiVersion: v1
kind: Pod
metadata:
  name: testpod1
  annotations:
     k8s.v1.cni.cncf.io/networks: hostdevice-net
spec:
  containers:
  - name: appcntr1
    image: <image>
    imagePullPolicy: IfNotPresent
    securityContext:
      capabilities:
        add: ["IPC_LOCK"]
    command:
      - sh
      - -c
      - sleep inf
    resources:
      requests:
        nvidia.com/hostdev: '1'
        nvidia.com/gpu: '1'
      limits:
        nvidia.com/hostdev: '1'
        nvidia.com/gpu: '1'

Network Operator Deployment in SR-IOV Legacy Mode

Warning

The SR-IOV Network Operator will be deployed with the default configuration. You can override these settings using a CLI argument, or the ‘sriov-network-operator’ section in the values.yaml file. For more information, refer to the Project Documentation.

Warning

This deployment mode supports SR-IOV in legacy mode.

First install the Network Operator with NFD and SRIOV Network Operator enabled: values.yaml:

nfd:
  enabled: true
sriovNetworkOperator:
  enabled: true

Once the Network Operator is installed create a NicClusterPolicy with: * DOCA driver * Secondary network * Multus CNI * IPoIB CNI * IPAM CNI plugin

 apiVersion: mellanox.com/v1alpha1
 kind: NicClusterPolicy
 metadata:
   name: nic-cluster-policy
 spec:
   ofedDriver:
     image: doca-driver
     repository: nvcr.io/nvidia/mellanox
     version: 24.10-0.3.2.0-0
     forcePrecompiled: false
     imagePullSecrets: []
     terminationGracePeriodSeconds: 300
     startupProbe:
       initialDelaySeconds: 10
       periodSeconds: 20
     livenessProbe:
       initialDelaySeconds: 30
       periodSeconds: 30
     readinessProbe:
       initialDelaySeconds: 10
       periodSeconds: 30
     upgradePolicy:
       autoUpgrade: true
       maxParallelUpgrades: 1
       safeLoad: false
       drain:
         enable: true
         force: true
         podSelector: ""
         timeoutSeconds: 300
         deleteEmptyDir: true
   secondaryNetwork:
     cniPlugins:
       image: plugins
       repository: ghcr.io/k8snetworkplumbingwg
       version: v1.5.0
       imagePullSecrets: []
     multus:
       image: multus-cni
       repository: ghcr.io/k8snetworkplumbingwg
       version: v4.1.0
       imagePullSecrets: []
     ipamPlugin:
       image: whereabouts
       repository: ghcr.io/k8snetworkplumbingwg
       version: v0.7.0
       imagePullSecrets: []

Following the deployment, the Network Operator should be configured, and sriovnetwork node policy and K8s networking should be deployed.

The sriovnetwork-node-policy.yaml configuration file for such a deployment:

apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetworkNodePolicy
metadata:
  name: policy-1
  namespace: nvidia-network-operator
spec:
  deviceType: netdevice
  mtu: 1500
  nicSelector:
    vendor: "15b3"
    pfNames: ["ens2f0"]
  nodeSelector:
    feature.node.kubernetes.io/pci-15b3.present: "true"
  numVfs: 8
  priority: 90
  isRdma: true
  resourceName: sriov_resource

The sriovnetwork.yaml configuration file for such a deployment:

apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetwork
metadata:
  name: "example-sriov-network"
  namespace: nvidia-network-operator
spec:
  vlan: 0
  networkNamespace: "default"
  resourceName: "sriov_resource"
  ipam: |-
    {
      "datastore": "kubernetes",
      "kubernetes": {
        "kubeconfig": "/etc/cni/net.d/whereabouts.d/whereabouts.kubeconfig"
      },
      "log_file": "/tmp/whereabouts.log",
      "log_level": "debug",
      "type": "whereabouts",
      "range": "192.168.101.0/24"
    }

Warning

The ens2f0 network interface name has been chosen from the following command output: kubectl -n nvidia-network-operator get sriovnetworknodestates.sriovnetwork.openshift.io -o yaml.

...

status:
  interfaces:
  - deviceID: 101d
    driver: mlx5_core
    linkSpeed: 100000 Mb/s
    linkType: ETH
    mac: 0c:42:a1:2b:74:ae
    mtu: 1500
    name: ens2f0
    pciAddress: "0000:07:00.0"
    totalvfs: 8
    vendor: 15b3
  - deviceID: 101d
    driver: mlx5_core
    linkType: ETH
    mac: 0c:42:a1:2b:74:af
    mtu: 1500
    name: ens2f1
    pciAddress: "0000:07:00.1"
    totalvfs: 8
    vendor: 15b3

...

Wait for all required pods to be spawned:

# kubectl get pod -n nvidia-network-operator | grep sriov
network-operator-sriov-network-operator-544c8dbbb9-vzkmc          1/1     Running   0          5d
sriov-device-plugin-vwpzn                                         1/1     Running   0          2d6h
sriov-network-config-daemon-qv467                                 3/3     Running   0          5d
# kubectl get pod -n nvidia-network-operator
NAME                                            READY   STATUS    RESTARTS   AGE
cni-plugins-ds-kbvnm                            1/1     Running   0          5d
cni-plugins-ds-pcllg                            1/1     Running   0          5d
kube-multus-ds-5j6ns                            1/1     Running   0          5d
kube-multus-ds-mxgvl                            1/1     Running   0          5d
mofed-ubuntu20.04-ds-2zzf4                      1/1     Running   0          5d
mofed-ubuntu20.04-ds-rfnsw                      1/1     Running   0          5d
whereabouts-nw7hn                               1/1     Running   0          5d
whereabouts-zvhrv                               1/1     Running   0          5d
...

The pod.yaml configuration file for such a deployment:

apiVersion: v1
kind: Pod
metadata:
  name: testpod1
  annotations:
    k8s.v1.cni.cncf.io/networks: example-sriov-network
spec:
  containers:
  - name: appcntr1
    image: <image>
    imagePullPolicy: IfNotPresent
    securityContext:
      capabilities:
        add: ["IPC_LOCK"]
    resources:
      requests:
        nvidia.com/sriov_resource: '1'
      limits:
        nvidia.com/sriov_resource: '1'
    command:
    - sh
    - -c
    - sleep inf

SR-IOV Network Operator Deployment – Parallel Node Configuration for SR-IOV

Warning

This feature is supported only for Vanilla Kubernetes deployments with SR-IOV Network Operator.

To apply SR-IOV configuration on several nodes in parallel, create a SriovNetworkPoolConfig CR and specify the maximum number or percentage of nodes that can be unavailable at the same time:

sriov-network-pool-config-number.yaml

apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetworkPoolConfig
metadata:
  name: pool-1
  namespace: nvidia-network-operator
spec:
  maxUnavailable: "20"
  nodeSelector:
    - matchExpressions:
      - key: some-label
        operator: In
        values:
          - val-2
    - matchExpressions:
      - key: other-label
        operator: "Exists"

sriov-network-pool-config-percent.yaml

apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetworkPoolConfig
metadata:
  name: pool-1
  namespace: nvidia-network-operator
spec:
  maxUnavailable: "10%"
  nodeSelector:
    - matchExpressions:
      - key: some-label
        operator: In
        values:
          - val-2
    - matchExpressions:
      - key: other-label
        operator: "Exists"

Upgrade from NVIDIA Network Operator v24.1.0

To upgrade SR-IOV Network operator you need to create SriovNetworkPoolConfig CR with the number of nodes to be configured in a parallel as we did in SriovOperatorConfig` in previous releases.

E.g.: old method to configure nodes in a parallel:

kubectl patch sriovoperatorconfigs.sriovnetwork.openshift.io -n nvidia-network-operator default --patch '{ "spec": { "maxParallelNodeConfiguration": 5 } }' --type='merge'

New method to configure nodes in a parallel:

sriov-network-pool-config-new.yaml

apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetworkPoolConfig
metadata:
  name: pool-1
  namespace: nvidia-network-operator
spec:
  maxUnavailable: "5"
  nodeSelector:
    - matchExpressions:
      - key: node-role.kubernetes.io/master
            operator: Exists

SR-IOV Network Operator Deployment – Parallel NIC Configuration for SR-IOV

Warning

This feature is supported only for Vanilla Kubernetes deployments with SR-IOV Network Operator.

To apply SriovNetworkNodePolicy on several nodes in parallel, specify the featureGates option in the SriovOperatorConfig CRD:

kubectl patch sriovoperatorconfigs.sriovnetwork.openshift.io -n nvidia-network-operator default --patch '{ "spec": { "featureGates": { "parallelNicConfig": true  } } }' --type='merge'

SR-IOV Network Operator Deployment – SR-IOV Using the systemd Service

To enable systemd SR-IOV configuration mode, specify the configurationMode option in the SriovOperatorConfig CRD:

kubectl patch sriovoperatorconfigs.sriovnetwork.openshift.io -n nvidia-network-operator default --patch '{ "spec": { "configurationMode": "systemd"} }' --type='merge'

Network Operator Deployment with an SR-IOV InfiniBand Network

Network Operator deployment with InfiniBand network requires the following:

  • NVIDIA DOCA Driver and OpenSM running. OpenSM runs on top of the NVIDIA DOCA Driver stack, so both the driver and the subnet manager should come from the same installation. Note that partitions that are configured by OpenSM should specify defmember=full to enable the SR-IOV functionality over InfiniBand. For more details, please refer to this article.

  • InfiniBand device – Both the host device and switch ports must be enabled in InfiniBand mode.

  • rdma-core package should be installed when an inbox driver is used.

First install the Network Operator with NFD and SR-IOV Network Operator enabled: values.yaml

nfd:
  enabled: true
sriovNetworkOperator:
  enabled: true

Once the Network Operator is installed create a NicClusterPolicy with: * DOCA driver * Secondary network * Multus CNI * Container Networking Plugins * IPAM plugin

 apiVersion: mellanox.com/v1alpha1
 kind: NicClusterPolicy
 metadata:
   name: nic-cluster-policy
 spec:
   ofedDriver:
     image: doca-driver
     repository: nvcr.io/nvidia/mellanox
     version: 24.10-0.3.2.0-0
     forcePrecompiled: false
     imagePullSecrets: []
     terminationGracePeriodSeconds: 300
     startupProbe:
       initialDelaySeconds: 10
       periodSeconds: 20
     livenessProbe:
       initialDelaySeconds: 30
       periodSeconds: 30
     readinessProbe:
       initialDelaySeconds: 10
       periodSeconds: 30
     upgradePolicy:
       autoUpgrade: true
       maxParallelUpgrades: 1
       safeLoad: false
       drain:
         enable: true
         force: true
         podSelector: ""
         timeoutSeconds: 300
         deleteEmptyDir: true
   secondaryNetwork:
     cniPlugins:
       image: plugins
       repository: ghcr.io/k8snetworkplumbingwg
       version: v1.5.0
       imagePullSecrets: []
     multus:
       image: multus-cni
       repository: ghcr.io/k8snetworkplumbingwg
       version: v4.1.0
       imagePullSecrets: []
     ipamPlugin:
       image: whereabouts
       repository: ghcr.io/k8snetworkplumbingwg
       version: v0.7.0
       imagePullSecrets: []

sriov-ib-network-node-policy.yaml

apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetworkNodePolicy
metadata:
  name: infiniband-sriov
  namespace: nvidia-network-operator
spec:
  deviceType: netdevice
  mtu: 1500
  nodeSelector:
    feature.node.kubernetes.io/pci-15b3.present: "true"
  nicSelector:
    vendor: "15b3"
  linkType: IB
  isRdma: true
  numVfs: 8
  priority: 90
  resourceName: mlnxnics

sriov-ib-network.yaml

apiVersion: sriovnetwork.openshift.io/v1
kind: SriovIBNetwork
metadata:
  name: example-sriov-ib-network
  namespace: nvidia-network-operator
spec:
  ipam: |
    {
      "type": "whereabouts",
      "datastore": "kubernetes",
      "kubernetes": {
        "kubeconfig": "/etc/cni/net.d/whereabouts.d/whereabouts.kubeconfig"
      },
      "range": "192.168.5.225/28",
      "exclude": [
       "192.168.5.229/30",
       "192.168.5.236/32"
      ],
      "log_file": "/var/log/whereabouts.log",
      "log_level": "info"
    }
  resourceName: mlnxnics
  linkState: enable
  networkNamespace: default

sriov-ib-network-pod.yaml

apiVersion: v1
kind: Pod
metadata:
  name: test-sriov-ib-pod
  annotations:
    k8s.v1.cni.cncf.io/networks: example-sriov-ib-network
spec:
  containers:
    - name: test-sriov-ib-pod
      image: centos/tools
      imagePullPolicy: IfNotPresent
      command:
        - sh
        - -c
        - sleep inf
      securityContext:
        capabilities:
          add: [ "IPC_LOCK" ]
      resources:
        requests:
          nvidia.com/mlnxics: "1"
        limits:
          nvidia.com/mlnxics: "1"

Network Operator Deployment with an SR-IOV InfiniBand Network with PKey Management

Network Operator deployment with InfiniBand network requires the following:

  • NVIDIA DOCA Driver and OpenSM running. OpenSM runs on top of the NVIDIA DOCA Driver stack, so both the driver and the subnet manager should come from the same installation. Note that partitions that are configured by OpenSM should specify defmember=full to enable the SR-IOV functionality over InfiniBand. For more details, please refer to this article.

  • NVIDIA UFM running on top of OpenSM. For more details, please refer to the project documentation.

  • InfiniBand device – Both the host device and the switch ports must be enabled in InfiniBand mode.

  • rdma-core package should be installed when an inbox driver is used.

Current limitations:

  • Only a single PKey can be configured per workload pod.

  • When a single instance of NVIDIA UFM is used with several K8s clusters, different PKey GUID pools should be configured for each cluster.

Warning

ib-kubernetes-ufm-secret should be created before NicClusterPolicy.

ufm-secret.yaml

apiVersion: v1
kind: Secret
metadata:
  name: ib-kubernetes-ufm-secret
  namespace: nvidia-network-operator
stringData:
  UFM_USERNAME: "admin"
  UFM_PASSWORD: "123456"
  UFM_ADDRESS: "ufm-host"
  UFM_HTTP_SCHEMA: ""
  UFM_PORT: ""
data:
  UFM_CERTIFICATE: ""

First install the Network Operator with NFD enabled: values.yaml

nfd:
  enabled: true
sriovNetworkOperator:
  enabled: true
  resourcePrefix: "nvidia.com"

Once the Network Operator is installed create a NicClusterPolicy with: * DOCA driver * ibKubernetes * Secondary network * Multus CNI * Container Networking plugins * IPAM Plugin

 apiVersion: mellanox.com/v1alpha1
 kind: NicClusterPolicy
 metadata:
   name: nic-cluster-policy
 spec:
   ofedDriver:
     image: doca-driver
     repository: nvcr.io/nvidia/mellanox
     version: 24.10-0.3.2.0-0
     forcePrecompiled: false
     imagePullSecrets: []
     terminationGracePeriodSeconds: 300
     startupProbe:
       initialDelaySeconds: 10
       periodSeconds: 20
     livenessProbe:
       initialDelaySeconds: 30
       periodSeconds: 30
     readinessProbe:
       initialDelaySeconds: 10
       periodSeconds: 30
     upgradePolicy:
       autoUpgrade: true
       maxParallelUpgrades: 1
       safeLoad: false
       drain:
         enable: true
         force: true
         podSelector: ""
         timeoutSeconds: 300
         deleteEmptyDir: true
   ibKubernetes:
     image: ib-kubernetes
     repository: ghcr.io/mellanox
     version: v1.0.2
     imagePullSecrets: []
     pKeyGUIDPoolRangeStart: 02:00:00:00:00:00:00:00
     pKeyGUIDPoolRangeEnd: 02:FF:FF:FF:FF:FF:FF:FF
     ufmSecret: "ufm-secret"
   nvIpam:
     image: nvidia-k8s-ipam
     repository: ghcr.io/mellanox
     version: v0.2.0
     imagePullSecrets: []
     enableWebhook: false
   secondaryNetwork:
     cniPlugins:
       image: plugins
       repository: ghcr.io/k8snetworkplumbingwg
       version: v1.5.0
       imagePullSecrets: []
     multus:
       image: multus-cni
       repository: ghcr.io/k8snetworkplumbingwg
       version: v4.1.0
       imagePullSecrets: []

Create IPPool object for nv-ipam

apiVersion: nv-ipam.nvidia.com/v1alpha1
kind: IPPool
metadata:
  name: pool1
  namespace: nvidia-network-operator
spec:
  subnet: 192.168.0.0/16
  perNodeBlockSize: 100
  gateway: 192.168.0.1
  nodeSelector:
    nodeSelectorTerms:
    - matchExpressions:
        - key: node-role.kubernetes.io/worker
          operator: Exists

Wait for NVIDIA DOCA Driver to install and apply the following CRs:

sriov-ib-network-node-policy.yaml

apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetworkNodePolicy
metadata:
  name: infiniband-sriov
  namespace: nvidia-network-operator
spec:
  deviceType: netdevice
  mtu: 1500
  nodeSelector:
    feature.node.kubernetes.io/pci-15b3.present: "true"
  nicSelector:
    vendor: "15b3"
  linkType: IB
  isRdma: true
  numVfs: 8
  priority: 90
  resourceName: mlnxnics

sriov-ib-network.yaml

apiVersion: "k8s.cni.cncf.io/v1"
kind: NetworkAttachmentDefinition
metadata:
  name: ib-sriov-network
  annotations:
    k8s.v1.cni.cncf.io/resourceName: nvidia.com/mlnxnics
spec:
  config: '{
  "type": "ib-sriov",
  "cniVersion": "0.3.1",
  "name": "ib-sriov-network",
  "pkey": "0x6",
  "link_state": "enable",
  "ibKubernetesEnabled": true,
  "ipam": {
      "type": "nv-ipam",
      "poolName": "pool1"
    }
}'

Note

To use the IB network with Pkey management feature with RDMA isolation, use the following sriov-ib-network.yaml:

apiVersion: "k8s.cni.cncf.io/v1"
kind: NetworkAttachmentDefinition
metadata:
  name: ib-sriov-network
  annotations:
    k8s.v1.cni.cncf.io/resourceName: nvidia.com/mlnxnics
spec:
  config: '{
  "cniVersion": "0.3.1",
  "name": "ib-sriov-network",
  "plugins": [
  {
    "type": "ib-sriov",
    "pkey": "0x6",
    "link_state": "enable",
    "ibKubernetesEnabled": true,
    "ipam": {
      "type": "nv-ipam",
      "poolName": "pool1"
    }
  },
  {
    "type": "rdma"
  }
  ]
}'

sriov-ib-network-pod.yaml

apiVersion: v1
kind: Pod
metadata:
  name: test-sriov-ib-pod
  annotations:
    k8s.v1.cni.cncf.io/networks: ib-sriob-network
spec:
  containers:
    - name: test-sriov-ib-pod
      image: centos/tools
      imagePullPolicy: IfNotPresent
      command:
        - sh
        - -c
        - sleep inf
      securityContext:
        capabilities:
          add: [ "IPC_LOCK" ]
      resources:
        requests:
          nvidia.com/mlnxics: "1"
        limits:
          nvidia.com/mlnxics: "1"

Network Operator Deployment for DPDK Workloads with NicClusterPolicy

This deployment mode supports DPDK applications. In order to run DPDK applications, HUGEPAGE should be configured on the required K8s Worker Nodes. By default, the inbox operating system driver is used. For support of cases with specific requirements, OFED container should be deployed.

Network Operator deployment with:

  • Host Device Network

  • DPDK pod

nicclusterpolicy.yaml

 apiVersion: mellanox.com/v1alpha1
 kind: NicClusterPolicy
 metadata:
   name: nic-cluster-policy
 spec:
   ofedDriver:
     image: doca-driver
     repository: nvcr.io/nvidia/mellanox
     version: 24.10-0.3.2.0-0
   sriovDevicePlugin:
     image: sriov-network-device-plugin
     repository: ghcr.io/k8snetworkplumbingwg
     version: v3.7.0
      config: |
       {
         "resourceList": [
             {
                 "resourcePrefix": "nvidia.com",
                 "resourceName": "rdma_host_dev",
                 "selectors": {
                     "vendors": ["15b3"],
                     "devices": ["1018"],
                     "drivers": ["mlx5_core"]
                 }
             }
         ]
       }
   secondaryNetwork:
     cniPlugins:
       image: plugins
       repository: ghcr.io/k8snetworkplumbingwg
       version: v1.5.0-amd64
     ipamPlugin:
       image: whereabouts
       repository: ghcr.io/k8snetworkplumbingwg
       version: v0.7.0-amd64
     multus:
       image: multus-cni
       repository: ghcr.io/k8snetworkplumbingwg
       version: v4.1.0

host-device-net.yaml

apiVersion: mellanox.com/v1alpha1
kind: HostDeviceNetwork
metadata:
  name: example-hostdev-net
spec:
  networkNamespace: "default"
  resourceName: "rdma_host_dev"
  ipam: |
    {
      "type": "whereabouts",
      "datastore": "kubernetes",
      "kubernetes": {
        "kubeconfig": "/etc/cni/net.d/whereabouts.d/whereabouts.kubeconfig"
      },
      "range": "192.168.3.225/28",
      "exclude": [
       "192.168.3.229/30",
       "192.168.3.236/32"
      ],
      "log_file" : "/var/log/whereabouts.log",
      "log_level" : "info"
    }

pod.yaml

apiVersion: v1
kind: Pod
metadata:
  name: testpod1
  annotations:
    k8s.v1.cni.cncf.io/networks: example-hostdev-net
spec:
  containers:
  - name: appcntr1
    image: <dpdk image>
    imagePullPolicy: IfNotPresent
    securityContext:
      capabilities:
          add: ["IPC_LOCK"]
    volumeMounts:
      - mountPath: /dev/hugepages
        name: hugepage
    resources:
      requests:
        memory: 1Gi
        hugepages-1Gi: 2Gi
        nvidia.com/rdma_host_dev: '1'
    command: [ "/bin/bash", "-c", "--" ]
    args: [ "while true; do sleep 300000; done;" ]
  volumes:
   - name: hugepage
     emptyDir:
       medium: HugePages

Network Operator Deployment and OpenvSwitch offload

Warning

This feature is supported only for Vanilla Kubernetes deployments with SR-IOV Network Operator.

Warning

To use OFED container with this mode of operation, set the RESTORE_DRIVER_ON_POD_TERMINATION environment variable to false in the driver configuration section in the NicClusterPolicy. Restoration to the inbox driver is not supported for this feature.

Warning

Tech Preview feature.

Network Operator Configuration

Deploy network-operator by Helm with sriov-network-operator and nv-ipam.

First install the Network Operator with NFD enabled: values.yaml

sriovNetworkOperator:
  enabled: true

Once the Network Operator has been installed create a NicClusterPolicy with nv-ipam:

 apiVersion: mellanox.com/v1alpha1
 kind: NicClusterPolicy
 metadata:
   name: nic-cluster-policy
 spec:
   nvIpam:
     image: nvidia-k8s-ipam
     repository: ghcr.io/mellanox
     version: v0.2.0
     imagePullSecrets: []
     enableWebhook: false

Enable manageSoftwareBridges featureGate for sriov-network-operator

kubectl patch sriovoperatorconfigs.sriovnetwork.openshift.io -n nvidia-network-operator default --patch '{ "spec": { "featureGates": { "manageSoftwareBridges": true  } } }' --type='merge'

Create IPPool object for nv-ipam

apiVersion: nv-ipam.nvidia.com/v1alpha1
kind: IPPool
metadata:
  name: pool1
  namespace: nvidia-network-operator
spec:
  subnet: 192.168.0.0/16
  perNodeBlockSize: 100
  gateway: 192.168.0.1
  nodeSelector:
    nodeSelectorTerms:
    - matchExpressions:
        - key: node-role.kubernetes.io/worker
          operator: Exists

Prerequisites for Worker Nodes

Supported operating systems:

  • Ubuntu 22.04

  • RHEL 8.8

OpenvSwitch from the NVIDIA DOCA for Host package with doca-all or doca-networking profile should be installed on each worker node.

Check NVIDIA DOCA Official installation guide for details.

Supported OpenvSwitch dataplanes:

  • OVS-kernel

  • OVS-doca

Check OpenvSwitch Offload document to know about differences.

OVS-kernel

These steps are for OVS-kernel data plane, to use OVS-doca follow instructions from the relevant section.

Prepare Worker Nodes

Configure Open_vSwitch

ovs-vsctl set Open_vSwitch . other_config:hw-offload=true

Restart Open_vSwitch

systemctl restart openvswitch-switch.service
Sriov Network Operator Configuration

Create SriovNetworkNodePolicy for selected NIC

apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetworkNodePolicy
metadata:
  name: ovs-switchdev
  namespace: nvidia-network-operator
spec:
  eSwitchMode: switchdev
  mtu: 1500
  nicSelector:
    deviceID: 101d
    vendor: 15b3
  nodeSelector:
    node-role.kubernetes.io/worker: ""
  numVfs: 4
  isRdma: true
  linkType: ETH
  resourceName: switchdev
  bridge:
    ovs: {}

Create OVSNetwork CR

apiVersion: sriovnetwork.openshift.io/v1
kind: OVSNetwork
metadata:
  name: ovs
  namespace: nvidia-network-operator
spec:
  networkNamespace: default
  ipam: |
    {
      "type": "nv-ipam",
      "poolName": "pool1"
    }
  resourceName: switchdev

OVS-doca

These steps are for OVS-doca data plane, to use OVS-kernel follow instructions from the relevant section.

Prepare Worker Nodes

Configure hugepages

mkdir -p /hugepages
mount -t hugetlbfs hugetlbfs /hugepages
echo 4096 > /sys/devices/system/node/node0/hugepages/hugepages-2048kB/nr_hugepages

Note: for multi CPU system hugepages should be created for each NUMA node: node0, node1, …

Configure system to create hugepages on boot

echo "vm.nr_hugepages=8192" > /etc/sysctl.d/99-hugepages.conf

Note: this example is for a server with two CPU

Configure Open_vSwitch

ovs-vsctl --no-wait set Open_vSwitch . other_config:doca-init=true
ovs-vsctl set Open_vSwitch . other_config:hw-offload=true

Restart Open_vSwitch

systemctl restart openvswitch-switch.service
Sriov Network Operator Configuration

Create SriovNetworkNodePolicy for selected NIC

apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetworkNodePolicy
metadata:
  name: ovs-switchdev
  namespace: nvidia-network-operator
spec:
  eSwitchMode: switchdev
  mtu: 1500
  nicSelector:
    deviceID: 101d
    vendor: 15b3
  nodeSelector:
    node-role.kubernetes.io/worker: ""
  numVfs: 4
  isRdma: true
  linkType: ETH
  resourceName: switchdev
  bridge:
    ovs:
      bridge:
        datapathType: netdev
      uplink:
        interface:
          type: dpdk

Create OVSNetwork CR

apiVersion: sriovnetwork.openshift.io/v1
kind: OVSNetwork
metadata:
  name: ovs
  namespace: nvidia-network-operator
spec:
  networkNamespace: default
  ipam: |
    {
      "type": "nv-ipam",
      "poolName": "pool1"
    }
  resourceName: switchdev
  interfaceType: dpdk

Test Workload

apiVersion: apps/v1
kind: Deployment
metadata:
  name: ovs-offload
  labels:
    app: ovs-offload
spec:
  replicas: 2
  selector:
    matchLabels:
      app: ovs-offload
  template:
    metadata:
      labels:
        app: ovs-offload
      annotations:
        k8s.v1.cni.cncf.io/networks: ovs
    spec:
      containers:
      - name: ovs-offload-container
        command: ["/bin/bash", "-c"]
        args:
        - |
          while true; do sleep 1000; done
        image: mellanox/rping-test
        securityContext:
          capabilities:
            add: ["IPC_LOCK"]
        resources:
          requests:
            nvidia.com/switchdev: 1
          limits:
            nvidia.com/switchdev: 1

Troubleshooting OVS